Menu
The 85XX+ is an upgrade on the most successful model 85XX; additional capabilities have been added by way of multi-serial ports, Ethernet port, Profibus-DP, USB port, scanning speed and alphanumeric display.
- 85XX Scanner Monitor. Communicate Multi Point On/Off control Pipeline Heat Tracing circuit control 48 open collector outputs Channel to channel input isolation Weather proof / flame proof enclosure www.masibus.com [email protected] mSCAN Remote I/O for PLC/DCS/SCADA IP65 Front Fascia Ethernet.
- The scanner 85XX can be connected in RS-485/RS232 communication data link either in multi drop or repeat mode. Each scanner 85XX must have unique Serial Number. Two scanners may not have the same address. Entire range of addresses (1 to 99) may be used. Before starting any communication, choose a baud rate and protocol compatible to the host.
- Scanner 85XX+ Scanner/DAQ Module in harsh environment up to 50°C ambient temperature and 95% relative humidity (Non-Condensing). Free tips on how to lose belly fat fast how to complete identity theft in batman arkham city free website countdown clock masibus temperature scanner manual pdf As an Serial/Ethernet/Profibus RTU.
The 85XX + is an upgrade on the most successful model 85XX; additional capabilities have been added by way of multi-serial ports, Ethernet port, Profibus-DP, USB port, scanning speed and alphanumeric display. Modular and Expandable 85XX + is modular in architecture and Expandable, 5 I/O slots can accommodate a mix of Analog Input, Digital Input, Open collector output, Analog output or Relay.
85XX+ is modular in architecture and Expandable, 5 I/O slots can accommodate a mix of Analog Input, Digital Input, Open collector output, Analog output or Relay output to suit different applications in Power, water, Pipeline and Infrastructure industries. All field inputs are wired by Pre-Fab cables direct into panel terminals.
Manual dos desbravadores download. Manual do Desbravador. 12,589 likes 11 talking about this. Bem Vindo ao Portal do Manual do Desbravador! Entre e confira tudo que acontece no mundo dos.
Configuration 85XX+ is configured using the mSCAN+ software which is very user friendly; the unit can also be edited by front keyboard and display. The unit has numeric and alpha-numeric displays for value and tag display, Alarm/Trip and control status are displayed by discrete LEDs on front fascia.
Communication
85XX+ comes with one RS485 Port as a standard, a second RS485 Port, Ethernet Port & Profibus DP Port are options to enhance the communication capabilities of the unit and use it as an RTU, Alarm controller or protection device for motors, transformers, etc. It has optional USB port for logged data retrieval.
Alarm Control8 Relay and 24 OC outputs can be freely mapped as alarm/trip or control set point.
Analog Output An isolated 4-20mA Re-transmission output option is available for onward transmission to PLC/DCS/Recorder/SCADA. User manual hybrid smartwatch jacqueline black stainless steel. Max 8 output per card is possible.
FEATURES:-
FEATURES:-
Masibus Temperature Scanner 85xx Manual Pdf
- Universal input for each Analog Input
- IP65 for Weather proof protection
- Easy Programming by front Touch sense keypad
- Fast Sampling rate with instantaneous relay action
- Four relays for alarm/trip
- RS485 Serial communication port for remote monitoring
- Multiple Levels of configuration and password protection
- Comprehensive Alarm/Trip logic programming